Electrical Engineering & Design

Data Center & Mission-Critical

Power-system analysis, redundancy modeling, and critical-power engineering for high-availability facilities.

Overview

Data center power systems live or die by their ability to ride through every failure mode without dropping load. We model 2N, 2(N+1), and distributed redundant topologies; verify selectivity through every transfer; size UPS, generator, and battery systems for the actual IT load profile; and produce the documentation a Tier III or Tier IV commissioning agent will demand. We work directly with white-space designers, MEP firms, and GC partners like Turner Construction on facility builds and retrofits.

What's included

Scope of work

Topology selection and one-line development (N, N+1, 2N, 2(N+1))

UPS sizing for IT load with proper diversity and growth assumptions

Generator and paralleling switchgear sizing

Battery sizing per IEEE 485 / IEC 60896

Load flow, short-circuit, coordination, and arc-flash for all operating modes

Tier III / Tier IV documentation per Uptime Institute

Concurrent maintainability verification

Methodology

How the engagement runs

A consistent process means predictable timelines, fewer surprises, and a defensible record if anyone (AHJ, insurance, OSHA) asks how the work was done.

  1. 01

    Topology and redundancy modeling

    Failure-mode analysis on each proposed topology before equipment sizing begins.

  2. 02

    Sizing and selection

    UPS, generator, battery, and switchgear sized against the actual IT growth curve, not nameplate IT load.

  3. 03

    Studies

    Load-flow, short-circuit, coordination, and arc-flash run for every operating mode including maintenance bypass.

  4. 04

    Documentation

    Tier certification documentation, commissioning script, and operations runbook prepared.

  5. 05

    Commissioning support

    On-site through Level 4 / Level 5 site integration and IST.

Stamped

100%

Every deliverable PE-stamped by a licensed engineer in the project state. Across all 24 registered states.

Response

1 day

We respond to every inquiry within one business day with a scoped proposal and a real timeline.

Veteran-owned

VOSB / SDVOSB

SAM.gov registered. UEI H6HAZKAD4LJ7 · CAGE 08E02. Set-aside eligible.

When you need it

Triggers

  • New build or major capacity expansion
  • Tier upgrade (Tier II → Tier III)
  • Concurrent maintainability finding
  • Cooling or IT density increase that drives new electrical needs

What you receive

Deliverables

  • PE-stamped electrical CDs
  • Full power-system study package
  • Tier certification documentation
  • Commissioning script and IST procedure

Ready to scope your data center & mission-critical engagement?

Send us the basics (facility type, equipment, timeline) and we’ll respond with a scoped proposal within one business day.