MEP Engineering & Design

Data Center & Mission-Critical

Power-system analysis, redundancy modeling, and critical-power engineering for high-availability facilities.

Overview

Data center power systems live or die by their ability to ride through every failure mode without dropping load. We model 2N, 2(N+1), and distributed redundant topologies; verify selectivity through every transfer; size UPS, generator, and battery systems for the actual IT load profile; and produce the documentation a Tier III or Tier IV commissioning agent will demand. We work directly with white-space designers, MEP firms, and GC partners like Turner Construction on facility builds and retrofits.

What's included

Scope of work

Topology selection and one-line development (N, N+1, 2N, 2(N+1))

UPS sizing for IT load with proper diversity and growth assumptions

Generator and paralleling switchgear sizing

Battery sizing per IEEE 485 / IEC 60896

Load flow, short-circuit, coordination, and arc-flash for all operating modes

Tier III / Tier IV documentation per Uptime Institute

Concurrent maintainability verification

Methodology

How the engagement runs

We agree on inputs, responsibilities, and deliverables before the work begins, then keep the design decisions connected through each stage.

Data Center & Mission-Critical: how the engagement runs

  1. 1Topology and redundancy modeling
    Failure-mode analysis on each proposed topology before equipment sizing begins.
  2. 2Sizing and selection
    UPS, generator, battery, and switchgear sized against the actual IT growth curve, not nameplate IT load.
  3. 3Studies
    Load-flow, short-circuit, coordination, and arc-flash run for every operating mode including maintenance bypass.
  4. 4Documentation
    Tier certification documentation, commissioning script, and operations runbook prepared.
  5. 5Commissioning support
    On-site through Level 4 / Level 5 site integration and IST.

Engineering scope

Project-specific

Disciplines, deliverables, licensing, and sealing requirements confirmed for your project before work begins.

Response

1 day

We respond to every inquiry within one business day to discuss scope, next steps, and the information needed for a proposal.

Veteran-owned

VOSB / SDVOSB

SAM.gov registered. UEI H6HAZKAD4LJ7 · CAGE 08E02. Set-aside eligible.

When you need it

Triggers

  • →New build or major capacity expansion
  • →Tier upgrade (Tier II → Tier III)
  • →Concurrent maintainability finding
  • →Cooling or IT density increase that drives new electrical needs

What you receive

Deliverables

  • PE-stamped electrical CDs
  • Full power-system study package
  • Tier certification documentation
  • Commissioning script and IST procedure