Power System Studies

Load Flow Analysis

Steady-state power-flow studies that verify voltage regulation, conductor sizing, and transformer loading at every operating mode.

Overview

Load flow tells you whether your facility will operate within design limits at every plausible loading and switching scenario: full-load summer peak, partial-load emergency mode, generator-only operation. We model the system in ETAP or EasyPower, evaluate voltage at every bus, transformer and cable loading at every branch, and identify violations of ANSI C84.1 voltage limits or thermal capacity before they manifest as field problems.

What's included

Scope of work

Full-load, partial-load, and emergency-mode load-flow cases

Voltage regulation evaluation at every bus per ANSI C84.1

Transformer, cable, and busway loading evaluation

Power factor and reactive demand assessment

Capacitor / reactor sizing recommendations

PE-stamped report with results tables and one-line annotations

Methodology

How the engagement runs

A consistent process means predictable timelines, fewer surprises, and a defensible record if anyone (AHJ, insurance, OSHA) asks how the work was done.

  1. 01

    Load survey

    Installed and projected loads compiled by zone with diversity factors applied.

  2. 02

    Scenario definition

    Operating modes defined: normal, generator-on-utility-off, partial bus, and so on.

  3. 03

    Simulation

    Newton-Raphson load flow run for each scenario in ETAP or EasyPower.

  4. 04

    Compliance review

    Bus voltages and branch loading compared to ANSI C84.1, equipment ratings, and NEC ampacity.

  5. 05

    Recommendations

    Conductor up-sizing, tap-changer adjustments, or PF correction recommended where needed.

Stamped

100%

Every deliverable PE-stamped by a licensed engineer in the project state. Across all 24 registered states.

Response

1 day

We respond to every inquiry within one business day with a scoped proposal and a real timeline.

Veteran-owned

VOSB / SDVOSB

SAM.gov registered. UEI H6HAZKAD4LJ7 · CAGE 08E02. Set-aside eligible.

When you need it

Triggers

  • New large load addition (chiller, VFD, EV charger bank)
  • Voltage complaints in specific zones of the facility
  • Pre-design phase of any major service or distribution upgrade
  • Microgrid or on-site generation feasibility study

What you receive

Deliverables

  • PE-stamped load-flow report
  • Bus voltage and branch loading tables for every studied case
  • Annotated single-line diagram
  • Sizing recommendations for any flagged equipment